PLANET MG-120 2-port RS232/422/485 Modbus Gateway

PLANET MG-120 2-port RS232/422/485 Modbus Gateway
PLANET MG-120 2-port RS232/422/485 Modbus Gateway
PLANET MG-120 2-port RS232/422/485 Modbus Gateway
PLANET MG-120 2-port RS232/422/485 Modbus Gateway
PLANET MG-120 2-port RS232/422/485 Modbus Gateway
PLANET MG-120 2-port RS232/422/485 Modbus Gateway
PLANET MG-120 2-port RS232/422/485 Modbus Gateway
PLANET MG-120 2-port RS232/422/485 Modbus Gateway
PLANET MG-120 2-port RS232/422/485 Modbus Gateway
  • Διαθεσιμοτητα: Άμεσα Διαθέσιμο
  • Κατασκευαστης: PLANET
  • Κωδικος Προϊοντος: MG-120
  • Βαρος: 0.51kg
  • Διαστασεις: 7.00 x 9.70 x 2.60
181,95€
Χωρίς ΦΠΑ: 146,74€

Standard Modbus TCP/RTU/ASCII Network Integration

PLANET MG-120 2-port RS232/422/485 Modbus Gateway supports the standard Modbus Protocol, which makes it possible for converting any Modbus Protocols between Modbus TCP, Modbus RTU, and Modbus ASCII for all supported hardware interfaces. Its serial protocol can be used for industrial automation where SCADA or HMI system is in place. 

Moreover, its network integration can be upgraded from the SNMP network to the automated Modbus TCP network, which brings interconnection over Ethernet longer distances, thus making a network infrastructure more flexible. 

A Conversion Bridge for Flexible Network Deployment

The MG-120 can be a conversion bridge between the equipment with the Modbus RTU/ASCII Protocol and the administrator workstations that run the Modbus TCP/IP Protocol. The RS232/422/485 serial interface of the MG-120 provides the Modbus RTU/ASCII operation mode and various baud rate options to meet the demand of integration between the Modbus TCP/IP Protocol, Modbus RTU Master/Slave Protocol and Modbus ASCII Master/Slave Protocol. 

The advantage of having the MG-120 is to assist users to build an environment between the Modbus TCP Protocol and the Modbus RTU/ASCII Protocol easily, thus offering an application solution to the control equipment without Ethernet ports, and the control equipment can only control through a PC workstation or control panel. 

In addition, the effective integration solution of Modbus Ethernet devices, Modbus serial equipment or multi Modbus master / slave in a hybrid network brings the following:

  • Master mode supports up to 32 TCP slave connection requests
  • Slave mode supports up to 32 TCP master connections

 

Remote Management 

The MG-120 makes the connected Modbus RTU/ASCII equipment become IP-based facilities and is able to connect to the Modbus TCP/IP network via its R232/422/485 serial interface and 10/100BASE-TX RJ45 Ethernet port. It provides a remote web management and telnet Interface for efficient remote network management. The MG-120 also provides PLANET Modbus Gateway utility tool and supports PLANET Smart Discovery utility to help network administrator to easily get the current IP subnet address information or change the IP subnet address setting of the MG-120.

Modbus Serial Port State Monitoring

The MG-120 shows the details of the total bytes transmitted and received on the RS232/422/485 serial interface, and the detailed total number of frames transmitted and received on the remote web/telnet management interface. This function allows network administrator to check the status and statistics of the MG-120 via the single RS232/422/485 serial interface.

RTU/ASCII Master to Multi Modbus TCP/IP Slaves

The MG-120 can act as a bridge between the RTU/ASCII master equipment and the multi-TCP/IP slave equipment in a Modbus TCP/IP networking environment to control multi-TCP/IP slave equipment via the RTU/ASCII master equipment.

 

Multi Modbus TCP/IP Master to RTU/ASCII Slaves

The MG-120 can operate as a bridge between the multi-TCP/IP master equipment and the RTU/ASCII slave equipment in a Modbus TCP/IP networking environment to control the RTU/ASCII slave equipment via the multi-TCP/IP master equipment.

Serial Interface

  • Two DB9 interfaces support RS232, 2-wire RS485, 4-wire RS485 and RS422 standards
  • Asynchronous serial data rates up to 921600bps

 

Ethernet Interface

  • 1-port 10/100BASE-TX RJ45 with auto MDI/MDI-X function

 

Management Function

  • Built-in IP-based Web interface and telnet interface for remote management
  • Software Protocol supports Modbus TCP, Modbus RTU, Modbus ASCII, IP, ARP, DHCP and DNS
  • Supports RTU Master, RTU Slave, ASCII Master, and ASCII Slave four serial operation modes via management interface
  • Master mode supports 32 TCP slave connection requests
  • Slave mode supports 32 TCP master connections
  • PLANET Modbus Gateway utility for finding client device on the network
  • PLANET Smart Discovery utility automatically finds the client devices on the network
  • Firmware upgrade/configuration backup and restore via HTTP protocol

 

Case and Installation

  • -10 to 60 degrees C operating temperature
  • Reset button for resetting to factory default
Serial Interface
Serial Ports2 x DB9 male
Serial StandardsRS232
RS422
4-wire RS485
2-wire RS485
Baud Rate (Data Rate)50bps to 921Kbps
Data Bits5, 6, 7, 8
Stop Bit1, 1.5, 2
Parity TypeOdd, Even, None, Space, Mark
Flow ControlRTS/CTS and DTR/DSR (RS232 only)
XON/XOFF
Pin Assignment
PinRS232RS422
RS485-4W
RS485-2W
1DCDTxD+--
2RxDTxD---
3TxDRxD-Data-
4DTRRxD+Data+
5GNDGNDGND
6DSR----
7RTS----
8CTS----
9------
Operation ModeRTU Master/RTU Slave/ASCII Master/ASCII Slave
Master mode: Supports up to 32 TCP slave connection requests
Slave mode: Supports up to 32 TCP master connection requests
Ethernet Interface
Ethernet Ports1 x RJ45
Standard10/100BASE-TX
Distance100m
ESD Protection6KV
Hardware
InstallationDIN-rail kit and wall-mount ear
Dimensions (W x D x H)97 x 70 x 26mm
Weight189 g
LED IndicatorsSystem: Link
TP Port: Link/Active
Serial Port: Active
Power RequirementsExternal Power Adaptor 5V DC, 2A max.
Power Consumption5.5 watts (max.)
EnclosureMetal
Reset Button< 5 sec: System reboot
> 5 sec: Factory default
Management
Management InterfacesWeb management
Telnet Console management
Windows-based MB VCOM Utility management
SNMPv1, v2c / SNMP Trap
UNI-NMS monitoring
PLANET Smart Discovery Utility
IP VersionIPv4
Operation ModeRTU Master
RTU Slave
ASCII Master
ASCII Slave
Virtual COM Utility Platform SupportsWindows-based Only:
Windows XP
Windows Server 2003
Windows 7
Windows Server 2008
Windows 8 (Must install the latest version of WinPcap)
Windows Server 2012 (Must install the latest version of WinPcap)
Windows 10
Fault AlarmRecord: System log / SNMP trap
TimeNTP
SecurityAccessible IP (white list)
SNMPSNMP v1 and v2c
Standards Conformance
Regulatory ComplianceFCC Part 15 Class A,
CE Certification Class A
StandardsIEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX
RFC 768 UDP
RFC 793 TFTP
RFC 791 IP
RFC 792 ICMP
RFC 854 Telnet
RFC 958 NTP
RFC 1908 SNMPv2c
RFC 2068 HTTP
RFC 2131 DHCP Client
EIA/TIA RS232/422/485
Regulatory ApprovalRoHS
Environment
Operating Temperature-10 ~ 60 degrees C
Storage Temperature-10 ~ 70 degrees C
Humidity5 ~ 95% (non-condensing)

 

Datasheet

DateVersionDescriptionDownload
2020-07-241.0MG-120

 

Quick Guide

DateVersionDescriptionDownload
2020-07-031.0Initial release.

 

User's Manual

DateVersionDescriptionDownload
2020-11-301.0Initial release.

 

Utility

DateVersionDescriptionDownload
2021-05-172007221630_0904_1334_1010Initial release.
*Note: This utility is only for the MG-110, MG-120, MG-115A, IMG-2100T, IMG-2102T, IMG-2102TS, IMG-2105AT, IMG-2200T, and IMG-2400Tand NOT compatible with IMG-110 Tand IMG-120T.