- Διαθεσιμοτητα: Άμεσα Διαθέσιμο
- Κατασκευαστης: PLANET
- Κωδικος Προϊοντος: IMG-2102T
- Βαρος: 0.60kg
- Διαστασεις: 8.78 x 3.20 x 13.50
Standard Industrial Modbus TCP/RTU/ASCII Network Integration
PLANET has added the Industrial Modbus TCP/IP Protocol to its easily-integrated industrial management level products that come with SCADA/HMI system and other data acquisition systems on factory floors. Moreover, the industrial IT SNMP network is upgraded to the Industrial automation Modbus TCP/IP network. PLANET industrial management level products with the Modbus TCP/IP Protocol offer flexible network connectivity solutions for the industrial automation environment.
To complete the industrial automation environment application solution, PLANET has announced a first industrial level 1-port RS232/422/485 Modbus Gateway, IMG-210xT Series, a bridge that converts between Modbus TCP/IP Protocol and Modbus RTU/ASCII Protocol. It features a wide operating temperature range from -40 to 75 degrees C and a compact but rugged IP30 metal housing.
A Conversion Bridge for Flexible Network Deployment
The IMG-210xT Series can be a conversion bridge between the equipment with the Modbus RTU/ASCII Protocol and the administrator workstations that run the Modbus TCP/IP Protocol. The RS232/422/485 serial interface of the IMG-210xT Series provides the Modbus RTU/ASCII operation mode and various baud rate options to meet the demand of integration between the Modbus TCP/IP Protocol, Modbus RTU Master/Slave Protocol and Modbus ASCII Master/Slave Protocol.
The advantage of having the IMG-210xT series is to assist users to build an industrial environment between the Modbus TCP/IP Protocol and the Modbus RTU/ASCII Protocol easily, thus offering an application solution to the industrial control equipment without Ethernet ports and the industrial control equipment can only control through an industrial PC workstation or industrial control panel.
In addition, the effective integration solution of Modbus Ethernet devices, Modbus serial equipment or multi Modbus master / slave in an industrial hybrid network brings the following:
- Master mode supports up to 32 TCP slave connection requests
- Slave mode supports up to 32 TCP master connections
Remote Management
The IMG-210xT series makes the connected industrial Modbus RTU/ASCII equipment become IP-based facilities and is able to connect to the Modbus TCP/IP network via its RS232/422/485 serial interface and 100BASE-FX Ethernet port. It provides a remote web management and telnet Interface for efficient remote network management. The IMG-210xT series also provides PLANET Modbus Gateway utility tool and supports PLANET Smart Discovery utility to help network administrator to easily get the current IP subnet address information or change the IP subnet address setting of the IMG-210xT series.
Modbus Serial Port State Monitoring
The IMG-210xT series shows the details of the total bytes transmitted and received on the RS232/422/485 serial interface, and the detailed total number of frames transmitted and received on the remote web/telnet management interface. This function allows network administrator to check the status and statistics of the IMG-210xT series via the single RS232/422/485 serial interface.
Stable Performance in Hardened Environment Design
The IMG-210xT series provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curb-side traffic control cabinets. Its operating temperature ranging from -40 to 75 degrees C allows the IMG-210xT series to be placed in almost any difficult environment.
The IMG-210xT series is equipped with a compact IP30-rated metal case that allows wall mounting for efficient use of cabinet space. The IMG-210xT series also provides an integrated power supply source with wide-ranging voltages (9 to 48V DC / 24V AC) ideally suitable for worldwide operation with high availability applications.
Dual Power Input for High Availability Network System
The IMG-210xT series features a strong dual power input system with wide-ranging voltages (9V~48V DC / 24V AC) incorporated into customer’s automation network to enhance system reliability and uptime. In the example below, when Power Supply 1 fails to work, the hardware failover function will be activated automatically to keep powering the IMG-210xT series via Power Supply 2 without any break of operation.
RTU/ASCII Master to Multi Modbus TCP/IP Slaves
The IMG-210xT series can act as a bridge between the industrial RTU/ASCII master equipment and the multi-industrial TCP/IP slave equipment in a Modbus TCP/IP networking environment to control multi-industrial TCP/IP slave equipment via the industrial RTU/ASCII master equipment.
Multi Modbus TCP/IP Master to RTU/ASCII Slaves
The IMG-210xT series can operate as a bridge between the multi-industrial TCP/IP master equipment and the industrial RTU/ASCII slave equipment in a Modbus TCP/IP networking environment to control the industrial RTU/ASCII slave equipment via the multi-industrial TCP/IP master equipment.
Serial Interface
- One DB9 interface that supports RS232
- One terminal block interface that supports 2-wire RS485 and 4-wire RS422/RS485 operation
- Asynchronous serial data rates up to 921600bps
Ethernet Interface
- Choice of fiber connectors: SC/LC fiber connector or multi-mode/single mode fiber connector
Management Function
- Built-in IP-based Web interface and telnet interface for remote management
- Software Protocol supports Modbus TCP, Modbus RTU, Modbus ASCII, IP, ARP, DHCP and DNS
- Supports RTU Master, RTU Slave, ASCII Master, and ASCII Slave four serial operation modes via management interface
- Master mode supports 32 TCP slave connection requests
- Slave mode supports 32 TCP master connections
- PLANET Modbus Gateway utility for finding client device on the network
- PLANET Smart Discovery utility automatically finds the client devices on the network
- Firmware upgrade/configuration backup and restore via HTTP protocol
Industrial Case and Installation
- IP30 metal case
- DIN-rail and wall-mount designs
- Redundant power design - 9 to 48V DC / 24V AC, redundant power with reverse polarity protection
- Supports 6000 VDC Ethernet ESD protection
- Free fall, shock-proof and vibration-proof for industries
- Supports extensive LED indicators for network diagnosis
- -40 to 75 degrees C operating temperature
- Reset button for resetting to factory default
Serial Interface | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Serial Ports | IMG-2105AT 1 x DB9 male for RS232 1 x 4-Pin Terminal block for RS422 / RS485 IMG-2102T 1 x DB9 male for RS232 1 x 4-Pin Terminal block for RS422 / RS485 IMG-2102TS 1 x DB9 male for RS232 1 x 4-Pin Terminal block for RS422 / RS485 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Serial Standards | RS232 / 4-wire RS422 or RS485 / 2-wire RS485 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Baud Rate (Data Rate) | 50bps to 921Kbps | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Data Bits | 5, 6, 7, 8 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Stop Bit | 1, 1.5, 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Parity Type | Odd, Even, None, Space, Mark | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow Control | RTS/CTS and DTR/DSR (RS232 only) XON/XOFF | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Signals | RS232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND RS422: Tx+, Tx-, Rx+, Rx-, GND 4-wire RS485: Tx+, Tx-, Rx+, Rx-, GND 2-wire RS485: Data A (+), Data B (-), GND | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pin Assignment | Serial Port
4-pin Terminal Block
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Operation Mode | RTU Master/RTU Slave/ASCII Master/ASCII Slave Master mode: Supports up to 32 TCP slave connection requests Slave mode: Supports up to 32 TCP master connection requests | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ethernet Interface | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ethernet Port | IMG-2105AT: 1 x SFP IMG-2102T/ICS-2102TS: 1 x Duplex SC | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Standard | 100BASE-FX | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Connector | IMG-2105AT: LC IMG-2102T/ICS-2102TS: Duplex SC | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fiber Mode | IMG-2105AT: Single mode or multi-mode (may vary on SFP module) IMG-2102T: Multi-mode IMG-2102TS: Single mod | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Transmission Mode | Full duplex | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Distance | IMG-2105AT: 2km to 120km (may vary on SFP module) IMG-2102T: 2km IMG-2102TS: 30km | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Cable | IMG-2105AT: 50 or 62.5/125μm multi-mode fiber cable 9/125μm single-mode cable IMG-2102T: 50/125μm or 62.5/125μm multi-mode fiber cable IMG-2102TS: 9/125μm single-mode cable | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
ESD Protection | 6KV | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Surge Protection | 2KV | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hardware | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Installation | DIN-rail kit and wall-mount ear | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Enclosure | IP 30 metal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions (W x D x H) | 32 x 87.8 x 135 mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | IMG-2105AT: 390g IMG-2102T: 386g IMG-2102TS: 391g | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
LED Indicators | System: Power 1, Power 2, Fault, SYS SFP: Link/Active Serial Port: Tx and Rx | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power Requirements | 9~48V DC / 24V AC, redundant power with reverse polarity protection | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power Consumption | IMG-2105AT: Full Loading 9VDC: 0.44A (3.96 watts) 12VDC: 0.33A (4 watts) 24VDC: 0.17A (4.08 watts) 48VDC: 0.1A (4.8 watts) IMG-2102T: Full Loading 9VDC: 0.56A (5 watts) 12VDC: 0.42A (5 watts) 24VDC: 0.23A (5.5 watts) 48VDC: 0.13A (6 watts) IMG-2102TS: Full Loading 9VDC: 0.56A (5 watts) 12VDC: 0.42A (5 watts) 24VDC: 0.23A (5.5 watts) 48VDC: 0.13A (6 watts) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Connector | Removable 6-pin terminal block for power input Pin 1/2 for Power 1, Pin 3/4 for fault alarm, Pin 5/6 for Power 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Alarm | Provides one relay output for power failure Alarm relay current carry ability: 1A @ DC 24V | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Reset Button | < 5 sec: System reboot > 5 sec: Factory default | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Management | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Management Interfaces | Web management Telnet Console management Windows-based MB VCOM Utility management SNMPv1, v2c / SNMP Trap UNI-NMS monitoring PLANET Smart Discovery Utility | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
IP Version | IPv4 and IPv6 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Operation Mode | RTU Master RTU Slave ASCII Master ASCII Slave | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Virtual COM Utility Platform Supports | Windows-based only: Windows XP Windows Server 2003 Windows 7 Windows Server 2008 Windows 8 (Must install the latest version of WinPcap) Windows Server 2012 (Must install the latest version of WinPcap) Windows 10 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fault Alarm | Record: System log / SNMP trap | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Time | NTP | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Security | Allow maximum 4 accessible IP address hosts/ranges | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
SNMP MIBs | RFC1213 MIB-II RFC1317 RS232-like MIB | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Standards Conformances | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Regulatory Compliance | FCC Part 15 Class A, CE Certification Class A RoHS | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Stability Testing | IEC60068-2-32 (Free fall) IEC60068-2-27 (Shock) IEC60068-2-6 (Vibration) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Standards | IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-FX RFC 768 UDP RFC 793 TFTP RFC 791 IP RFC 792 ICMP RFC 854 Telnet RFC 958 NTP RFC 1591 DNS (client only) RFC 1908 SNMPv2c RFC 2068 HTTP RFC 2131 DHCP Client RFC 2732 Format for Literal IPv6 Addresses in URL's RFC 3315 DHCPv6 Client RFC 3513 IPv6 Addressing Architecture RFC 3596 DNSv6 RFC 4443 ICMPv6 EIA/TIA RS232/422/485 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Environment | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Operating Temperature | -40 ~ 75 degrees C | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Storage Temperature | -40 ~ 85 degrees C | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
Humidity | 5 ~ 95% (non-condensing) |
Datasheet
Date | Version | Description | Download |
---|---|---|---|
2020-11-05 | 1.0 | IMG-2105AT / IMG-2102T / IMG-2102TS |
Quick Guide
Date | Version | Description | Download |
---|---|---|---|
2022-03-18 | 1.2 | Modify contents of Quick Guide. | |
2020-04-16 | 1.0 | Initial release. |
User's Manual
Date | Version | Description | Download |
---|---|---|---|
2020-10-08 | 1.0 | Release for IMG-2x00T series. |
Utility
EC Declaration
Date | Version | Description | Download |
---|---|---|---|
2023-12-26 | 1.0 | EC Declaration. |